ComfortNET SZC 16 SEER Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Wärmepumpen ComfortNET SZC 16 SEER herunter. ComfortNET SZC 16 SEER Specifications [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
I
MPORTANT
S
AFETY
I
NSTRUCTIONS
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards. It is
the owner’s and installer’s responsibility to read and comply
with all safety information and instructions accompanying these
symbols. Failure to heed safety information increases the risk
of personal injury, property damage, and/or product damage.
HIGHVOL TAGE!
D
ISCONNECT
ALL
POWER
BEFORE
SERVICING
.
M
ULTIPLE
POWER
SOURCES
MAY
BE
PRESENT
.F
AILURE
TO
DO
SO
MAY
CAUSE
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
.
WARNING
ONLY
INDIVIDUALS
MEETING
THE
REQUIREMENTS
OF
AN
“E
NTRY
L
EVEL
T
ECHNICIAN
AS
SPECIFIED
BY
THE
A
IR
C
ONDITIONING
,H
EATING
AND
R
EFRIGERATION
I
NSTITUTE
(AHRI)
MAY
USE
THIS
INFORMATION
.A
TTEMPTING
TO
INSTALL
OR
REPAIR
THIS
UNIT
WITHOUT
SUCH
BACKGROU ND
MAY
RESULT
IN
PRODUCT
DAMAGE
,
PERSONAL
INJURY
,
OR
DEATH
.
,
AT
A
MINIMUM
,
WARNING
S
CROLL
EQUIPPED
UNITS
SHOULD
NEVER
BE
USED
TO
EVACUATE
THE
AIR
CONDITIONING
SYSTEM
.V
ACUUMS
THIS
LOW
CAN
CAUSE
INTERNAL
ELECT RICAL
ARCING
RESULTING
IN
A
DAMAGED
OR
FAILED
COMPRESSOR
.
CAUTION
IMPORTANT N OTE TO THE O WNER REGARDING P RODUCT
WARRANTY
Your warranty certificate is supplied as a separate document
with the unit installed by your contractor. Read the limited war-
ranty certificate carefully to determine what is and is not cov-
ered and keep the warranty certificate in a safe place. If you
are unable to locate the warranty certificate please contact
your installing contractor or contact customer service (877-
254-4729) to obtain a copy.
To receive the Lifetime Unit Replacement Limited Warranty
(good for as long as you own your home) and the 10-Year
Parts Limited Warranty for Amana
®
branded products, online
registration must be completed within 60 days of installation.
Online registration is not required in California or Quebec.
CONDENSING UNIT
HEAT PUMP
INSTALLATION & SERVICE REFERENCE
© 2009-2012 Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com -or- www.amana-hac.com
P/N: IO-348H Date: July 2012
To receive the Lifetime Compressor Limited Warranty (good for
as long as you own your home), the 10-Year Unit Replacement
Limited Warranty, and the 10-Year Parts Limited Warranty for
Goodman
®
branded products, online registration must be com-
pleted within 60 days of installation. Online registration is not
required in California or Quebec.
Complete warranty details available from your local dealer or,
for Goodman
®
brand products, visit www.goodmanmfg.com,
and for Amana
®
brand products, visit www.amana-hac.com.
IMPORTANT: To register your Goodman
®
brand unit, go to
www.goodmanmfg.com and click “Warranty Registration”.
Complete registration as prompted.
To register your Amana
®
brand unit, go to www.amana-hac.com
and click “Warranty Registration”. Complete registration as
prompted.
IMPORTANT:
Product limited warranty certificates for models currently in
production can be viewed at www.goodmanmfg or www.amana-
hac.com. If your model is not currently in production or does
not appear on the website, please contact your installing con-
tractor or contact customer service (877-254-4729) to obtain a
copy of your warranty certificate.
Each product overview page contains a Product Warranty link;
by clicking on it you will be able to view the limited warranty
coverage for that specific product. To view warranty registration
information, click on the Product Warranty text on the left navi-
gation panel on the home page of each website. The Online
Product Registration pages are located in this same section.
S
HIPPING
I
NSPECTION
Always keep the unit upright; laying the unit on its side or top
may cause equipment damage. Shipping damage, and subse-
quent investigation is the responsibility of the carrier. Verify
the model number, specifications, electrical characteristics,
and accessories are correct prior to installation. The distribu-
tor or manufacturer will not accept claims from dealers for trans-
portation damage or installation of incorrectly shipped units.
C
ODES
& R
EGULATIONS
This product is designed and manufactured to comply with
national codes. Installation in accordance with such codes and/
or prevailing local codes/regulations is the responsibility of the
installer. The manufacturer assumes no responsibility for equip-
ment installed in violation of any codes or regulations. Rated
performance is achieved after 72 hours of operation.Rated per-
formance is delivered at the specified airflow. See outdoor unit
specification sheet for split system models or product specifi-
cation sheet for packaged and light commercial models. Speci-
is a registered trademark of Maytag Corporation or its related companies and is used under
license to Goodman Company, L.P., Houston, TX. All rights reserved.
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - CONDENSING UNIT

IMPORTANT SAFETY INSTRUCTIONSThe following symbols and labels are used throughout thismanual to indicate immediate or potential safety hazards. It is

Seite 2 - -5° to +14° 8"

10d. If subcooling is high and superheat is low, adjustTXV valve to 7 to 9 ºF superheat and remove chargeto lower the subcooling to 5 to 7 ºFNOTE: Do

Seite 3

11SystemSystem Operating ModeAirflow Demand SourceCooling Heat PumpHeat Pump Heating OnlyHeat PumpHP + Electric Heat Strips> of Heat Pump or Air Ha

Seite 4 - IMPORTANT

12ACCESSING AND N AVIGATING THE A DVANCED FEATURES M ENUSThe advanced system features are accessed using theComfortNet™ thermostat. These advanced fe

Seite 5 - HIGHVOL TAGE!

13AIR C ONDITIONER/HEAT P UMP A DVANCED F EATURES M ENUSSubmenu Item Indication (for Display Only; not User Modifiable)Number of AC Stages (CL STG) Di

Seite 6 - 90 Minutes

14AIR C ONDITIONER/HEAT P UMP A DVANCED F EATURES M ENUS ( CONT’D)Submenu Item Indication (for Display Only; not User Modifiable)Mode (MODE) Displays

Seite 7 - WIRING DIAGRAM

15LED LED Status Indication Possible Causes Corrective Action(s) Notes & CautionsOff • Normal condition • None • None • None• Depress on

Seite 8 - REFRIGERANTUNDERPRESSURE!

16TROUBLESHOOTING INFORMATION: CONDENSING UNITFor detailed service information refer to the Remote Condensing Unit Service manual.ComplaintSystem Oper

Seite 9 - XPANSION

17TROUBLESHOOTING INFORMATION: UNITARY DIAGNOSTIC CODESDiagnostic/Status LED Codes ComfortNet™ Thermostat Only Symptoms of Abnormal Operation (Legacy

Seite 10 - AIRFLOW C ONSIDERATION

18TROUBLESHOOTING INFORMATION: UNITARY DIAGNOSTIC CODESDiagnostic/Status LED Codes ComfortNet™ Thermostat Only Symptoms of Abnormal Operation (Legacy

Seite 11 - CTK0* WIRING

19TROUBLESHOOTING INFORMATION: UNITARY DIAGNOSTIC CODESSymptoms of Abnormal Operation (Legacy & ComfortNet™ Thermostat) Diagnostic/Status LED Code

Seite 12 - DIAGNOSTICS

2fication sheets can be found at www.goodmanmfg.com forGoodman® brand products or www.amana-hac.com for Amana®brand products. Within either website, p

Seite 13

20TROUBLESHOOTING INFORMATION: UNITARY DIAGNOSTIC CODESDiagnostic/Status LED Codes ComfortNet™ Thermostat Only Symptoms of Abnormal Operation (Legacy

Seite 14 - SYSTEM TROUBLESHOOTING

21Diagnostic/Status LED Codes ComfortNet™ Thermostat Only Symptoms of Abnormal Operation (Legacy & ComfortNet™ Thermostat) Green Yellow Red Red

Seite 15

22TROUBLESHOOTING INFORMATION: UNITARY DIAGNOSTIC CODESDiagnostic/Status LED Codes ComfortNet™ Thermostat Only Symptoms of Abnormal Operation (Legacy

Seite 16

23Diagnostic/Status LED Codes ComfortNet™ Thermostat Only Symptoms of Abnormal Operation (Legacy & ComfortNet™ Thermostat) Green Yellow Red Red

Seite 17

24SPLIT SYSTEMSAIR CONDITIONING AND HEAT PUMP HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDATIONSWe strongly recommend a bi-annual maintenance checkup be

Seite 18

3SAFE REFRIGERANT HANDLINGWhile these items will not cover every conceivable situation,they should serve as a useful guide.TOAVOIDPOSSIBLEINJURY,E

Seite 19

4BURYING REFRIGERANT LINESIf burying refrigerant lines can not be avoided, use the followingchecklist.1. Insulate liquid and suction lines separately.

Seite 20

5REFRIGERANTUNDERPRESSURE!FAILURETOFOLLOWPROPERPROCEDURESMAYCAUSEPROPERTYDAMAGE,PERSONALINJURYORDEATH.WARNINGNOTE: Scroll compressors sh

Seite 21

6The unit also has legacy 24 VAC inputs to support non-com-municating systems. Route control wires through the low volt-age port and terminate in acc

Seite 22

7NOTE: The usage of both OD thermostats may require field provided mounting hardware and weatherized enclosures.COLOR CODESR- REDY1 - YELLOW 1Y2 P YEL

Seite 23

8SYSTEM START UPPOSSIBLEREF RIGERANTLEAK!TOAVOIDAPOSSIBL EREFRIGERANTLEA K,OPENTHESERVICEVALVESUNTILTHETOPOFTHESTEMIS1/8”FROMTHE

Seite 24 - SPLIT SYSTEMS

9EXPANSION VALVE SYSTEMTOPREVENTPERSONALINJURY,CAREFULLYCONNECTANDDISCONNECTMANIFOLDGAUGEHOSES.ESCAPINGLIQUIDREFRIGERANTCANCAUSEBURNS.

Kommentare zu diesen Handbüchern

Keine Kommentare